Americor Electronics, Ltd.   675 S. Lively Blvd.   Elk Grove Village   IL.   60007   Phone: 847-956-6200   Fax: 847-956-0300   Email: info@americor-usa.com

Home | About Us | Products Sales Representation | What's New | Contact Us

 

Single Phase Encapsulated

 Transformers

 

 

 

Single Phase Safety and Isolation Transformers - Single Phase In-Line Transformers

Transformers for the Lighting Industry

 

Back to Medical Transformers

Back to Index

To DC Power Supplies-Switching Power Supplies

 

Please Note:

All transformers can be supplied with different Input Voltage, Output Voltage and Output Power.

Please contact us for technical information.

 

All transformers  are made to customer specification.

In some cases transformers are available from Stock

type: MSP MSP

 

Single-phase transformer realized as
single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4
or single-phase safety transformer according
to DIN EN 61558, VDE 0570, part 2-6.
Terminals with screw connection.
Transformers in plastic casing,
type of enclosure IP 00, safety class II,
50/60 Hz, ta 40°C. 
type: TS TS

 

Single-phase transformer realized as
single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4
or single-phase safety transformer according
to DIN EN 61558, VDE 0570, part 2-6.
Terminals with screw connection.
Transformers in plastic casing,
type of enclosure IP 00, safety class II,
50/60 Hz, ta 40°C. 
type: TRSA 

TRSA

 

Single-phase transformer realized as
single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4
or single-phase safety transformer according
to DIN EN 61558, VDE 0570, part 2-6.
Terminals with screw connection,
50/60 Hz, ta 40°C (T 40/E), safety class II.
Transformers in plastic casing,
type of enclosure IP 54 (type TRSA). 
type: WTSG 

WTSG

 

 

Single-phase transformer realized as
single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4
or single-phase safety transformer according
to DIN EN 61558, VDE 0570, part 2-6.
Terminals with screw connection,
50/60 Hz, ta 40°C (T 40/E), safety class II.
Transformers in plastic casing,
type of enclosure IP 43 (type WTSG). 
type: TSG-S 

TSG-S

Single-phase safety transformer
according to DIN EN 61558, VDE 0570,
part 2-6.
Primary mains cable, secondary socket,
non-inherently short-circuit-proof.
Transformer in plastic casing, type of
enclosure IP 43, safety class II, 50/60 Hz,
ta 40°C. 
type: TSG-T

TSG-T

Single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4.
Primary mains cable, secondary socket,
non-inherently short-circuit-proof.
Transformer in plastic casing,
type of enclosure IP 43, safety class II,
50/60 Hz, ta 40°C. 
type: TG-TTG-T

 

Single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4.
Primary mains cable, secondary socket,
non-inherently short-circuit-proof.
Transformer in sheet steel casing,
type of enclosure IP 43, safety class II,
50/60 Hz, ta 40°C. 
type: TG-S

TG-S

 

Single-phase safety transformer according
to DIN EN 61558, VDE 0570, part 2-6.
Primary mains cable, secondary socket,
non-inherently short-circuit-proof.
Transformer in sheet steel casing,
type of enclosure IP 43, safety class II,
50/60 Hz, ta 40°C. 
type: TST

TST

 

Single-phase safety transformer according
to DIN EN 61558, VDE 0570, part 2-6.
Primary mains cable, secondary special
three-pole socket (plug included in delivery),
non-inherently short-circuit-proof.
Transformer in sheet steel casing,
type of enclosure IP 43, safety class II,
50/60 Hz, ta 40°C. 
type: KSTF

 

 

 

 

 

 

Single-phase transformer realized as
single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4
or single-phase safety transformer according
to DIN EN 61558, VDE 0570, part 2-6.
Primary mains cable, secondary socket,
non-inherently short-circuit-proof. Transformer encapsulated in gum casing, resistant to shock,
type of enclosure IP 54, safety class II,
50/60 Hz. 
type: KSTK

KSTK

 

Single-phase transformer realized as
single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4
or single-phase safety transformer according
to DIN EN 61558, VDE 0570, part 2-6.
Primary mains cable, secondary socket,
non-inherently short-circuit-proof. Transformer encapsulated in plastic casing, resistant to shock
and temperature resistant up to 220°C,
type of enclosure IP 44, safety class II,
50/60 Hz, ta 40°C. 
type: KSTG

KSTG

 

 

Single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4.
Primary mains cable, secondary socket,
non-inherently short-circuit-proof.
Transformer in sheet steel casing,
type of enclosure IP 43, safety class II,
50/60 Hz, ta 40°C. 

 

 

type: KSTG-V KSTG-V

 

Single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4.
Transformer in block type encapsulated,
safety class II, 50/60 Hz, ta 40°C.
Type KSTG-V type of enclosure IP 44,
type KAWN-GV type of enclosure IP 65. 

 

type: KAWN-GV

KAWN-GV

Single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4.
Transformer in block type encapsulated,
safety class II, 50/60 Hz, ta 40°C.
Type KSTG-V type of enclosure IP 44,
type KAWN-GV type of enclosure IP 65. 

 

type: IHB-T-1  IHB-T-1

 

Single-phase transformer realized as single-phase
isolating transformer according to DIN EN 61558,
VDE 0570, part 2-4 or single-phase
safety transformer according to DIN EN 61558,
VDE 0570, part 2-6.
Primary mains cable, secondary socket.
Transformer encapsulated in plastic casing,
type of enclosure IP 43, non-inherently
short-circuit-proof, safety class II,
50/60 Hz, ta 40°C. 
type: IHB-T-2

IHB-T-2

 

Single-phase transformer realized as single-phase
isolating transformer according to DIN EN 61558,
VDE 0570, part 2-4 or single-phase
safety transformer according to DIN EN 61558,
VDE 0570, part 2-6.
Primary mains cable, secondary socket.
Transformer encapsulated in plastic casing,
type of enclosure IP 43, non-inherently
short-circuit-proof, safety class II,
50/60 Hz, ta 40°C. 
type: IHB-VT

IHB-VT

Single-phase in-line auto transformer
according to DIN EN 61558, VDE 0570,
part 2-13.
Transformer encapsulated into plastic casing
with handgrip, type of enclosure IP 21,
non-inherently short-circuit-proof,
safety class I, 50/60 Hz, ta 40°C. 
type: MMGHK

MMGHK

Lighting transformer executed as single-phase safety transformer according to DIN EN 61558, VDE 0570, part 2-6 in combination with
VDE 0710 part 14.
Separate windings.
Mains cable (without plug), primary fuse incorporated, secondary flexible connection
cable. Transformer encapsulated in white
plastic casing, safety class II, 50/60 Hz,
ta 40°C. 

  Power Cords | Adapters | Power Inlets | Shielded Conduits | EMI/RFI General Purpose Filters also Medical Grade Approved | AC-DC Plug-In Transformers, Wall Adapters, Switching Power Supplies | Fans | Wire Harnesses | Relays | Piezo Electric Buzzers and Speakers | Solenoids | Transformers, Domestic and International | Terminal Strips