Medical
Power Supplies |
|
Single and Three Phase
Transformers for the supply of Medical Rooms
Single Phase Isolation
Transformers |
|
|
type:
KOP-L |
Single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-15
as well as DIN VDE 0107/10.94. Shielding winding
between primary and secondary winding.
In every branch one PTC-resistor wrapped.
Connections: Terminals with screw connection,
prepared for safety class II, 50/60 Hz,
ta 40°C, dip impregnation.
|
type: KOP
 |
Single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-15
as well as DIN VDE 0107/10.94. Shielding winding
between primary and secondary winding.
In every branch one PTC-resistor wrapped.
Connections: Terminals with screw connection,
prepared for safety class II, 50/60 Hz,
ta 40°C, dip impregnation.
 |
| type: DOP-L

|
Three-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-15
as well as DIN VDE 0107/10.94. Shielding winding
between primary and secondary winding.
In every branch one PTC-resistor wrapped.
Connections: Terminals with screw connection,
prepared for safety class II, 50/60 Hz,
ta 40°C, dip impregnation.
|
type: DOP
 |
Three-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-15
as well as DIN VDE 0107/10.94. Shielding winding
between primary and secondary winding.
In every branch one PTC-resistor wrapped.
Connections: Terminals with screw connection,
prepared for safety class II, 50/60 Hz,
ta 40°C, dip impregnation.
|
| type: TG-MED-2

|
Single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4
and.EN 60601-1, DIN VDE 0107/10.94.
Primary mains cable, secondary two parallel
grounding outlets.
Primary fuse. Transformer in sheet steel casing,
color RAL 7035, type of enclosure IP 43,
safety class I, 50/60 Hz, ta 40°C.
 |
type: TG-MED-1

|
Single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-4
and. EN 60601-1, DIN VDE 0107/10.94.
Primary mains cable, secondary two parallel
grounding outlets.
Primary fuse. Transformer in sheet steel casing,
color RAL 7035, type of enclosure IP 43,
safety class I, 50/60 Hz, ta 40°C.
|
| type: KOP-VG
|
Single-phase isolating transformer according
to DIN EN 61558, VDE 0570, part 2-15
as well as DIN VDE 0107/10.94. Shielding winding
between primary and secondary winding.
In every branch one PTC-resistor wrapped.
Connections: Terminals with screwed connection,
safety class II, 50/60 Hz, ta 40°C,
Transformer in block type encapsulated,
protection system IP 65.
Connection to terminals in a connector box.
|
type: MTDN-M

|
Single-phase safety - transformer
according to DIN EN 61558, VDE 0570,
part 2-6
Terminals with screwed connections
(6,3 x 0,8 mm), prepared for safety class II,
ta 40°C, 50/60 Hz, dip impregnation.
Shielding winding at terminal,
insulated foot angles, temperature switch
connected with terminals
Acc. UL 2601, EN 60601-1, VDE 0570,
VDE 0100-710
|
 
|